Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Article in Spanish | LILACS | ID: lil-771673

ABSTRACT

Introducción: La clorhexidina (CHX) en solución acuosa se hidroliza generando paracloroanilina (PCA), proceso acelerado por el aumento de temperatura y pH. El uso de ultrasonido endodóntico (USE), basado en fenómenos de oscilación, cavitación, microcorriente acústica, genera calor afectando la CHX. Objetivo Identificar y cuantificar in vitro cambios fisicoquímicos, temperatura y pH, y la cantidad de PCA formada con el uso de ultrasonido endodóntico sobre soluciones de CHX al 2 por ciento. Materiales y métodos La CHX 2 por ciento se activó durante 30, 60, 90 y 120 seg con USE a 24.500 Hz, midiendo antes y después de activación: pH, temperatura y cantidad de PCA, leyendo a 375 nm en curva de calibración de estándares de PCA y formación, registrando el espectro de absorción mediante espectrofotómetro UV-visible. Resultados El USE aumentó la temperatura en 1 °C independiente del tiempo de aplicación y acidificó la solución de CHX 2 por ciento, sin variaciones significativas en pH y temperatura. No se observó coloración ni formación de precipitado en muestras activadas por USE a los diferentes tiempos. Las muestras no presentaron valores medibles de PCA a 375 nm. Los espectros de absorción de CHX 2 por ciento y activadas por USE por más de 60 seg presentaron curvas espectrales, peaks y valores de absorbancia diferentes. Conclusiones El USE aumenta la temperatura y acidifica la solución de la CHX en todos los tiempos de aplicación. No se detectó presencia de PCA por espectrofotometría visible. Muestras activadas por USE por 60 seg o más presentan espectros de absorción diferentes a las muestras sin activar. Diferencias en los espectros de absorción entre CHX activadas con USE y con CHX sin activar indicarían degradación de la CHX y posible presencia de PCA.


Introduction: Chlorhexidine (CHX) in aqueous solution is hydrolysed to p-chloroaniline (PCA), a process accelerated by increasing temperature and pH. Using endodontic ultrasound based on oscillation phenomena, cavitation, and acoustic microstreaming generates heat, affecting the CHX. Objective The aim of this in vitro study was to identify and quantify the physical-chemical changes, temperature and pH, and the amount of PCA formed by increasing the temperature of 2 percent CHX by endodontic ultrasound. Materials and methods Samples of 2 percent CHX were activated for 30, 60, 90, and 120 seconds with endodontic ultrasound 24,500 Hz. The pH and temperature were measured before and after activation, as well as the formation and amount of PCA, by reading and recording the result obtained from a standard calibration curve reading at 375 nm in a UV-visible light spectrophotometer. Results Independent of time, ultrasound increased the temperature of 2 percent CHX by 1 °C and acidified the solution. No significant changes were recorded in pH and temperature. No staining or precipitates were observed in samples ultrasonically activated at different times. Samples read at 375 nm showed no measurable PCA values. Absorption spectra of 2 percent CHX and 2 percent CHX activated for more than 60 seconds showed different spectral curves, peaks, and absorbance values. Conclusions Ultrasound increased the temperature and acidified the solution of CHX for all application times. No PCA was detected by visible spectrophotometry. Absorption spectra of 2 percent CHX activated with ultrasound at different times differs from 2 percent CHX without activation. These differences indicate degradation of CHX and possible presence of PCA.


Subject(s)
Chlorhexidine/chemistry , Aniline Compounds/chemistry , Ultrasonics , Disinfectants/chemistry , Hydrogen-Ion Concentration , In Vitro Techniques , Spectrophotometry , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL